ITM6 Situations as TEC Events

Based on http://publib.boulder.ibm.com/infocenter/tivihelp/v24r1/index.jsp?topic=/com.ibm.itm.doc/itm_admin_6284.htm

The following table describes the meaning of the situation event statuses and the setting of the common slots in the generated Tivoli Enterprise Console event.

Situation integration_type situation_status master_reset_flag Notes
true N the first time the situation is true; U, all subsequent times Y None new, or updated event
reset U N None “closed” event
acknowledge U A None
start None S None no TEC event generated
stop U P None all opened situation events that originated from this monitoring server will be closed on the event server
startup error None X None no TEC event generated
ack expired U F re-open event
resurface U E None Ack is removed before expiration and situation is still true
hub start N None R close opened situation events from this hub monitoring server
hub restart N None R Ditto of above
hub SFO N None S close all opened situation events from the old primary hub monitoring server.
The name of the old primary hub is in the situation_origin slot.